Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-60display disabled-tests
2
display disabled-tests
This command lists the numbers for all maintenance tests that have been
disabled by INADS. These tests will not be available for background or demand
testing.
Est. Conn.
Establish Connection data from the data module forms
(Processor Interface, X.25, and PPP).
Ext
Extension number of the local data module for this link.
Type
Protocol for this link:
bx.25
(Processor Interface and X.25)
ppp
ethernet
Destination Number
Destination of the link as administered on the data module forms
(Processor Interface, X.25 and PPP).
DTE/DCE
Processor Interface administration from data module form
(Processor Interface only).
Conn. Mod.
Connected Data Module administration from data module form
(Processor Interface and X.25 only)
Name
Administered name from the data module forms (Processor
Interface, X.25, Ethernet, and PPP)
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
display
disabled-tests
[print |
schedule]
Report sent to printer
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
1
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
none none