DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-320test analog-testcall
2
test analog-testcall
This command performs facility diagnostic tests on an entire trunk group, an
individual trunk group member, an individual trunk port, or on all trunks on a
board, depending on the options entered. The type of test call, the far-end test
line number, and the various other parameters must be administered on the trunk
group form before executing the command. Normally, the user should only
invoke the full or supervision test. The other options are provided primarily for
testing when setting up an ATMS schedule.
Date Alarmed
Day, hour, and minute of alarm.
Alarm Count
Count of the current alarm entry versus the total number of alarms
to be tested.
Test results section
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Test No
The test being executed
Result
Test result: Fail, Pass, Abort, or No Board. If this field has conflict,
another user may be testing this hardware.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.