DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-82display system-parameters maintenance
2
Cleared Alarm
Notification
Enables the switch to originate a call to the OSS and send an
alarm resolution message whenever all previously-reported
Major and Minor alarms are resolved. Alarm Origination must be
activated in order for Cleared Alarm Notification to work. (no)
Restart Notification
Enables the switch to originate a call to the OSS and report any
system restarts caused by problems with the switch.
Suspension Threshold
The threshold for suspending Cleared Alarm Notification (1-15).
Some problems may cause alarms to be generated and then
resolved repeatedly. To detect these problems (by not sending
additional Cleared Alarm notifications to indicate a problem-
free system), the switch suspends Cleared Alarm Notification
when it has reported this administrable number of Cleared
Alarm notifications in a 24-hour period. A suspended Cleared
Alarm Notification is only enabled again with a successfully
completed “logoff” command, a system reset, or when the
threshold is changed. This field is irrelevant if Cleared Alarm
Notification or Alarm Origination is disabled.
Test Remote Access
Port
Specifies whether testing of the remote access port on the
SYSAM circuit pack is enabled. This field should read
yes
whenever there is an INADS line connected to the switch and
there is a maintenance contract in effect so that alarm
origination capability is maintained.
CPE Alarm Activation
Level
Indicates the minimum level (Major, Minor or Warning) at which
the Customer-Provided Equipment (CPE) alarm is activated. If
the level is
none
, the CPE does is not activated for any alarm.
(none)
NOTE:
The CPE alarm is always activated when the switch goes
into Emergency Transfer, regardless of the CPE Alarm
Activation Level setting.
Customer Access to
INADS Port
Provides the capability to prohibit access to system
administration and maintenance interface, via the INADS port
when using customer login ID’s. This field can only be activated
by Lucent services through system-parameters maintenance
administration.(no)
Repeat Dial Interval
(MMS)
Indicates the number of minutes that the system must wait
before attempting another call origination to an OSS. This timer
is triggered by the lack of a far-end acknowledgment. (7)