DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-657ETR-PT (Enhanced Tone Receiver Port)
3
no dial or touch tones during this interval, which probably will not
affect calls in progress, but could cause a call origination to abort
or cause a user to not get dial tone when going off hook.
7. If all tests pass and the alarm does not resolve, retest (
test tone
UUCSS long clear
).
8. If the test passes, terminate the repair process. If it fails, replace the
circuit pack at the customer’s convenience.
9. If the board is duplicated, switch to the standby side (
set tone
).
10. Test the alarmed board (test tone UUCSS long). This resets the
board and is required to reload on-board RAM associated with the
TN2182’s DSPs.
11. If all tests pass and the alarm does not resolve, retest with
test tone
UUCSS long clear
.
12. If the test passes, terminate the repair process. If it fails, replace the
board.
b. The ETR-PT lost its translation. Testing the ETR-PT is sufficient to reload its
translation. If testing the ETR port does not clear the error, then the
TN2182 circuit pack containing the defective ETR port should be replaced
at a time when it is convenient to remove a clock board from the system.
Follow the procedures described in the TONE-BD section for replacing a
tone/clock circuit pack.
c. This error indicates the (ETR-PT) Enhanced Tone Receiver port is having
problems detecting touch tones, call progress or MFC tones. If this error
type is persistently logged, then the TN2182 circuit pack containing the
defective ETR-PT should be replaced at a time it is convenient to remove a
clock board from the system. Follow the procedures described in the
TONE-BD section for replacing a tone/clock circuit pack.
d. The ETR-PT lost its translation. Testing the ETR-PT is sufficient to reload its
translation. If testing the ETR port does not clear the error, then the
TN2182 circuit pack containing the defective ETR port should be replaced
at a time when it is convenient to remove a clock board from the system.
Follow the procedures described in the TONE-BD section for replacing a
tone/clock circuit pack.