Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-130ATM-BCH (ATM B-Channel Trunk)
3
i. Error Type 3585: ISDN RESTART message received. Active calls have
been dropped.
The following Aux Data values (Error Type 3585 only) below represent the
trunk’s ISDN call state at the time Error 3585 occurred. This information
can be useful if users report dropped calls on the ISDN-PRI trunks.
j. Error Type 3841: the far-end rejected an ATM CES trunk selected by the
near-end 10 times. The ATM CES trunk may not be administered on the
far-end.
1. Get the physical name of the ATM trunk by noting the decimal
number in the
Aux Data
field.
2. Check administration for the named trunk on the far-end.
3. If problems persist, then busyout the ATM trunk to take it out of the
hunt group.
The WARNING alarm retires automatically whenever a called endpoint
answers an outgoing or incoming call that uses the alarmed trunk.
Aux
Data Description
0 An idle trunk received a restart.
10 An ISDN RESTART from the far-end has unexpectedly cleared a
call in the ACTIVE state (call stable, parties talking).
4
7
8
260 263
An ISDN RESTART from the far-end has unexpectedly cleared a
RINGING call.
1
3
6
9
265
An ISDN RESTART from the far-end has unexpectedly cleared a
call before the call entered the RINGING state.
11
12
19
531 267 268
An ISDN RESTART from the far-end has unexpectedly cleared a
call that was already in the process of clearing.
If this condition occurs frequently, the far-end may be trying to
clear trunks that appear to be in the “hung” state.
Continued on next page