Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-930PPP-PT (Control LAN Packet/Port)
3
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures to verify repair.
3. Clear the alarm (
test port UUCSSpp long clear
).
c.
Error Type 513
: PPP link lost end-to-end connectivity.
1. Test for hardware problem (
test port UUCSSpp long
).
2. Run TDM Looparound Test (#1285) and refer to repair procedures if
there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP
link.
d.
Error Type 769
: Port received an invalid frame, which
is greater than the maximum length
contains CRC errors
violates the link level protocol.
1. Test the port (
test port UUCSSpp long
).
2. Refer to TDM Port Looparound Test (#1285) to verify repair.
3. Clear the alarm (
test port UUCSSpp long clear
).
e.
Error Type 1281
: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
f.
Error Type 1537, 1538
: Some or all port sessions (sockets) are down.
1. Test the port (
test port UUCSSpp short
).
2. Refer to Session Status Test (#1286) repair procedure to verify
repair.
g.
Error Type 1793-1920
: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
If the switch indicates that: Then it:
Some of the sessions are down Raises off-board WARNING
All of the sessions are down Raises off-board MINOR alarm