DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-764MAPD-BD (MAPD Interface Circuit Pack TN802)
3
MAPD-BD (MAPD Interface Circuit
Pack TN802)
The TN802 Multiple Application Platform for DEFINITY (MAPD) circuit pack
allows sending voice and fax from DEFINITY ECS through the Internet to another
DEFINITY also having this feature or to other PBXs that are equipped with the
Internet Telephony Server (ITS-E).
Throughout this section the term TN802 means the MAPD IP trunk circuit pack.
Be sure to observe these special considerations for the TN802:
Port alarms on this circuit pack display as “TIE-DS1” in the Alarm and
Error logs.
The
reset board
command reboots the MAPD PC CPU, but
busyout
board
only busys out all of the emulated ports on the board.
Switch resets that take the switch out of service for more than 20 seconds
also cause the MAPD's PC to reboot, which takes several minutes to
complete.
Switch-demanded tests
Switch-demanded diagnostic tests on the TN802 do not run unless the Internet
trunking application is running on Windows NT
TM
, located on the circuit pack.
Feature limitations
The Internet trunking application relies on the single call scenario, or a direct,
point-to-point call that does not terminate at multiple DEFINITY nodes through
call processing. Table 3-320
describes the feature limitations for DEFINITY ECS.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
MAPD-BD MAJOR test board UUCSS sh MAPD Interface Circuit Pack
MAPD-BD MINOR test board UUCSS l MAPD Interface Circuit Pack
MAPD-BD WARNING test board UUCSS sh MAPD Interface Circuit Pack