Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-172ATM-EI (Expansion Interface Circuit Pack)
3
Table 3-71. ATM Board Error Query Test (#1259)
Error
Code
Te s t
Result Description/ Recommendation
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
XXYY FAIL On-board hardware or off-board signalling errors on the board. XX
indicates the on-board hardware error, and YY indicates the off-board
errors on the as shown in Table 3-72
.
1. Resolve any errors in error logs.
PASS No service effecting errors or alarms were detected on the circuit pack.
0NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board
(Error Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so,
check for hyperactivity (Error Type 1538). If hyperactive, use the
reset board UUCSS command.
3. Run the test again. If it fails, the NCE chip on board may be bad.
Replace the board and retest.
Continued on next page
Table 3-72. XXYY Error Codes for Test #1259
(ATM Board Error Query Test)
XX Aux Data Description
1 ATM framer chip failed
2 NCE chip failed
3 LANHO critical error
4 TDM Prog. logic device failed
5 All on-board DSPs failed
6 Receive network processor failed
7 Transmit network processor failed
8 Memory read failed
Continued on next page