Maintenance Objects
3-384CO-DS1 (DS1 CO Trunk)
3
DS1 CO Dial Tone Seizure Test (#314)
DS1CO Dial Tone Seizure Test checks the trunk’s signaling capability provided
by the DS1 Interface circuit pack. The maintenance software initiates the test by
sending a "seizure" message to the DS1 Interface circuit pack and expects an
"active" reply from the DS1 interface circuit pack. If the "active" message is
received, then the test passes. If no message is received and the timer expires,
the test is aborted. If the DS1 Interface circuit pack sends a "reorder" message
back to maintenance software, then the test fails.
The test
CANNOT
be run on a trunk if one of the following cases is true:
a. The trunk direction is administered as an incoming only trunk.
b. The trunk has been seized by a normal trunk call.
c. The trunk is administered with maintenance test disabled.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, an insane board is inserted, or the board is hyperactive
(see note below).
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, dispatch to check to ensure that there is a valid board
inserted.
Hyperactivity causes some special problems with the sequence suggested
above. If the ports are translated after issuing the list config command but
the
Vintage field reports that there is no board (when there really is a
board), then the busyout board and the release busy board commands
will not work (even though the reset board command will work). The
software puts the hyperactive board back in service after the hyperactivity
clears.