Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-672H323-SGRP (H.323 Signaling Group)
3
Notes:
a.
Error Type 1
: this error indicates that the C-LAN ethernet port used to
carry the signaling for this H.323 signaling group is out of service. To
determine which C-LAN had been administered for this signaling group,
find the near-end node name on the
signaling group
form; then find the
C-LAN with the same node name on the
ip-interfaces form
. Check for
errors on this C-LAN board.
b.
Error Type 257
: this error tracks failures of the H.323 signaling-group
PING test. See H.323 signaling-group PING test failures documented later
in this maintenance object.
c.
Error Type 513
: this error tracks excessive round trip delay of the H.323
signaling-group PING test (if the round-trip delay exceeds 4 seconds).
d.
Error Type:769
: this error indicates that test packets sent from a media
processor circuit pack to the far-end ip address specified on the
signaling-group
form have exceeded the IP latency and loss thresholds,
as administered on the
system-parameters maintenance
form.
Exceeding these thresholds indicates that the IP network may not be
providing sufficient quality service for adequate transmission of voice. If
the signaling group has been administered to enable BYPASS, then error
type 1025 should also occur.
e.
Error Type 1025
: this error indicates that the signaling group has been
placed into a BYPASS condition due to IP network congestion. The
signaling group accepts incoming calls, but all outgoing calls are denied.
The system routes these calls over a secondary route if one has been
administered.
f.
Error Type 1281
: this error implies that no MedPro resources are
in-service to provide media connections for the trunk members of the
signaling group. Check for errors against the MEDPRO and MEDPROPT
maintenance objects. This error causes all H323 B Channels to be in an
out-of-service near-end state.
g.
Error Type 1537
: this error indicates that the far end of the signaling
group is not ready to handle audio bearer. If the other end of this signaling
group is also a DEFINITY, this error means the DEFINITY on the other end
does not have MEDPRO in-service for its signaling group.
In the absence of error 1281, this error will place the H323 B Channels into
an out-of-service far-end state.