DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-651ETH-PT (Control LAN Ethernet)
3
Link Integrity Inquiry Test (#1282)
This non-destructive test queries the CLAN Ethernet port’s physical connections.
If: Then the test:
CLAN connection is present, Passes.
CLAN connection is absent, Fails.
There is no response, Aborts.
Table 3-270. TEST #1282 Link Integrity Inquiry Test
Error
Code
Tes t
Result Description/ Recommendation
1124 ABORT Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link
n
, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
1959 ABORT Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.