DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1147TRANS-ID (Translation-ID)
3
TRANS-ID (Translation-ID)
Both the system processor and the PCMCIA translation card have matching ID
numbers. When the system detects a mismatch between the two numbers, the
system:
■ raises a MAJOR off-board alarm (TRANS-ID) against ports 01A or 01B.
■ displays the warning:
TRANS-ID INTERVAL EXPIRATION: x days;
call Lucent distributor immediately.
x days is the grace
period during which only Lucent Services logins can save translations.
■ disables the add, change, remove, and duplicate commands if the
translation ID is not reset prior to the expiration of the grace period (
reset
translation-id
-- Lucent Services login required)
For information about changing the grace period, see ‘‘Changing the grace
period interval’’.
Clearing the alarm
■ Use the
reset system 3
command with the translation card that matches
the processor(s) in place to resolve the condition.
■ Otherwise, contact authorized Lucent Services personnel or distributor
immediately. They can reset the translation ID (
reset translation-id
).
NOTE:
Duplicated systems raise separate MAJOR, off-board TRANS-ID alarms
against SPE A (01A) or SPE B (01B).
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
TRANS-ID MAJOR N/A Translation-ID
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board Test to Clear Value
Any None N/A MAJOR OFF Reset the system (reset system 3)
with matching translation and
processor(s). Contact authorized
Lucent personnel to execute the reset
translation-id command (requires
Lucent Services login).