Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1147TRANS-ID (Translation-ID)
3
TRANS-ID (Translation-ID)
Both the system processor and the PCMCIA translation card have matching ID
numbers. When the system detects a mismatch between the two numbers, the
system:
raises a MAJOR off-board alarm (TRANS-ID) against ports 01A or 01B.
displays the warning:
TRANS-ID INTERVAL EXPIRATION: x days;
call Lucent distributor immediately.
x days is the grace
period during which only Lucent Services logins can save translations.
disables the add, change, remove, and duplicate commands if the
translation ID is not reset prior to the expiration of the grace period (
reset
translation-id
-- Lucent Services login required)
For information about changing the grace period, see ‘‘Changing the grace
period interval’’.
Clearing the alarm
Use the
reset system 3
command with the translation card that matches
the processor(s) in place to resolve the condition.
Otherwise, contact authorized Lucent Services personnel or distributor
immediately. They can reset the translation ID (
reset translation-id
).
NOTE:
Duplicated systems raise separate MAJOR, off-board TRANS-ID alarms
against SPE A (01A) or SPE B (01B).
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
TRANS-ID MAJOR N/A Translation-ID
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board Test to Clear Value
Any None N/A MAJOR OFF Reset the system (reset system 3)
with matching translation and
processor(s). Contact authorized
Lucent personnel to execute the reset
translation-id command (requires
Lucent Services login).