DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-646ETH-PT (Control LAN Ethernet)
3
b.
Error Type 513
: Link Integrity Inquiry Test (#1282) failed or CLAN port
detected loss of Ethernet link integrity.
Possible causes:
Cabling
Ethernet transceiver
1. Test the port (
test port UUCSSpp long).
2. If the Link Integrity Inquiry Test (#1282) fils, refer to its repair
procedure.
c. Error Type 769
: Port received invalid frame.
Invalid Ethernet frame errors occur when the frame
Contains a bad Cyclic Redundancy Check (CRC)
Is misaligned
1. Isolate the problem with the Ethernet Local Looparound Test
(#1278).
2. Test the port (
test port UUCSSpp long).
3. Verify the repair with the Ethernet Local Looparound Test (#1278).
4. Clear the alarm (test port UUCSSpp long clear
).
d.
Error Type 1281
: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
e.
Error Type 1537-1538
: Some or all sessions on a port are down.
1. Test the port (
test port UUCSSpp short
).
2. Refer to Session Status Test (#1286) repair procedure to verify
repair.
f.
Error Type 1793-1920
: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
If: Then the switch:
Some sessions are down Raises WARNING alarm on circuit pack
All sessions are down Raises MINOR alarm on circuit pack