Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-133ATM-BCH (ATM B-Channel Trunk)
3
Table 3-54. TEST #256 Service State Audit Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT Needed resources not available, port on a call or initializing
1. Run status trunk
grp#
/
mbr#
.
1. Check the results of Test #255.
1018 ABORT Maintenance disabled
1. Enable maintenance by entering y in the Maintenance Tests? field
on page 2 of the change trunk-group form.
1113 ABORT Signaling link failed
1. Run status trunk
grp#
/
mbr#
.
2. Check the results of Test #255.
3. See the ‘‘ATM-SGRP (ATM Signaling Group)’’ maintenance object.
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1116 ABORT Trunk not in Out-of-Service/Far-end state and country protocol other than 1
1117 ABORT Service-state audit message outstanding
1. Wait 2 minutes, then try again.
2100 ABORT Could not allocate needed resources
1. Retry the command up to 5 times at 1-minute intervals.
1113 FAIL Signaling link failed
1. See the ‘‘ATM-SGRP (ATM Signaling Group)’’
and ISDN-LNK (ISDN
Signaling Link Port) maintenance objects.
FAIL Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS 1. Wait 4 minutes, then check the Error Log for any new Error Type 3073.
If there are none, both sides of the ISDN connection agree on the
service state. The negotiation succeeded.
If there is a new 3073 error, then the negotiation failed (the request
timed out).
Continued on next page