DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1285XXX-BD (Common Port Circuit Pack)
3
XXX-BD (Common Port Circuit Pack)
The Common Port Circuit Pack Maintenance is a set of common tests used by all
the circuit packs with the generic hardware that interfaces with the TDM bus.
Circuit packs included in this category are listed on the following pages.
Notes:
a. All circuit pack suffixes (B,C, D, etc.) are also supported by the XXX-BD
(Common Port Circuit Pack) Maintenance documentation.
b. The XXX-BD designation is also used in the SAT display in the case where
a
reset board command
is issued to a circuit pack type which is in
conflict to the actual circuit pack type administered for that slot or when a
reset board
command is issued to an empty circuit pack slot.
When any of the Common Port Circuit Packs (except the TN754 Digital Line and
TN758 Pooled Modem circuit packs) are physically removed from the backplane,
no alarm is logged for approximately 11 minutes. In the case of the Digital Line
and Pooled Modem circuit packs, approximately 21 minutes elapse before an
alarm is logged. When a circuit pack that has been removed is alarmed, the
alarm type is minor and is classified as an on-board alarm. The time delay
permits maintenance activity to be performed without triggering an additional
alarm.
An alarm is logged only against a Common Port Circuit Pack on
which ports have been administered.
See the next Note.
NOTE:
In a heavily loaded system, the interval between the removal of a Common
Port Circuit Pack and the logging of the alarm may be several minutes
longer.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. Where P is the port network number (1); C is the carrier designation (for example, A, B, or
C); and SS is the address of the slot in the carrier where the circuit pack is located (for
example, 01, 02,...etc.)
Full Name of MO
XXX-BD
2
2. Refer to the appropriate circuit pack documentation to get the correct MO name
displayed in this field. It usually ends with BD.
MAJOR test board PCSS Common Port Circuit
Pack Maintenance
XXX-BD
2
MINOR test board PCSS Common Port Circuit
Pack Maintenance
XXX-BD
2
WARNING test board PCSS Common Port Circuit
Pack Maintenance