DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-303status sys-link
2
Output
The following example shows the output from the
status sys-link 01a0516
command.
If a faulted path exists in addition to the current path, the components making up
the faulted path display on page 2 of the report:
Field descriptions
Location
Port location (cabinet-carrier-slot-circuit)
Type/Chan
Type of system-link: PRI (ISDN-PRI signaling link)
Alarms
Highest alarm level currently logged against the components
making up the link.
Current Path
Operational status of the current path:
none
: link is down.
present
: current path displayed is valid.
Faulted Path
The status of the faulted path, if any:
present: path of the link has been faulted at least once.
none: no record of the link having gone down
default: default faulted path is being used
Last Fault
Date and time at which the most recent fault occurred
State
Whether the system link is
up
or
down
status sys-link 01a0516 Page 1 of 2
Location: 01a0516 Type/Chan: PRI Alarms: none
Current Path: present Faulted Path: present Last Fault: 04/30/1997 14:18
State: up
Current Hardware Path
Maintenance Maintenance
Location Name Alarms Location Name Alarms
01A PKT-INT major
PN 01 TDM-BUS none
status sys-link 01a0516 Page 2 of 2
Location: 01a0516 Type/Chan: PRI Alarms: none
Current Path: present Faulted Path: present Last Fault: 04/30/1997 14:18
State: up
Faulted Hardware Path
Maintenance Maintenance
Location Name Alarms Location Name Alarms