DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1021SYSTEM (System)
3
SYSTEM (System)
SYSTEM is generally used when software encounters a problem with either
hardware or itself and requests a restart to clear the problem. SYSTEM also logs
errors that cannot be associated with any single process. This is not a problem.
The initcauses log should also confirm that a software-requested restart was
performed.
Error Log Entries and Test to Clear Values
The Aux Data field may be 0 or the return code from a bad software call, and the
following examples in no way exhaust the possibilities. Often, two errors are
logged at the same time for each problem.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. SYSTEM only has errors associated with it and thus only appears in the Error Log
and not in the Alarm Log. There are no tests that can be run with SYSTEM.
Full Name of MO
SYSTEM None None SYSTEM
Table 3-453. System Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any None
8 (a) 0 None
9 (b) Any None
10 (c) Any None
21 (d) None
133(e) 0 None
355 (f) Any None
356 (g) Any None
601 (h) None
602 (i) None
603 (j) None