Maintenance Objects
3-506DIG-LINE (Digital Line)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-213. DIG-LINE Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
18 (c) 0 busyout port
PCSSpp
WARNING OFF rel port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40971 None
513 0 Station (Digital)
Audits Test (#17)
WARNING(
o)
OFF test port PCSSpp sh r 6
767 (f) 40964 None WARNING OFF
769 (g) 40963
40988
None WARNING OFF
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port PCSSpp sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MINOR/
WARNING
2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MINOR/
WARNING
3
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
ON test port PCSSpp l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
3840 (k) 40965 None
3840 (l) 40989 None
3841 (m) 41029 None
Continued on next page