DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-13ADX8D-PT (AUDIX Digital Port)
3
Station Lamp Updates Test (#16)
Station (Digital) Audits Test (#17)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and
that it never crosses over to time slots reserved for other connections. If the NPE
is not working correctly, one-way and noisy connections may be observed. This
test is part of a port’s Long Test Sequence, and it takes about 20 to 30 seconds to
complete.
Crosstalk testing is performed on both the primary information channel (voice)
and on the secondary information channel (data) associated with each DEFINITY
AUDIX port. If this test fails on either channel, the voice port is taken
out-of-service.
Table 3-6. TEST #9 NPE Crosstalk Test
Error
Code
Test
Result Description/Recommendation
1 ABORT During testing of the primary information channel, system resources may not
have been available. Also, the port may have been busy during the test.
1. Check the port status. Use the display port PCSSpp command to
determine the voice port extension of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, you must wait until the port is idle.
2. When the port is idle, retry the command at 1-minute intervals a
maximum of 5 times.
2 ABORT System resources may not have been available, or the port may have been
busy during the test.
1. Retry the command at 1-minute intervals a maximum of 5 times
1000 ABORT System resources required to run this test are not available. The port may be
in use.
1. Use the display port PCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in
use, you must wait until the port is idle before retesting.
2. When the port is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT System resources required to run this test are not available
1. Retry the command at 1-minute intervals a maximum of 5 times..
Continued on next page