System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address,
always investigate errors associated with the circuit pack and port first. Clearing
these error codes first may also clear errors generated against the endpoint.
When all circuit pack and port errors have been cleared, and errors still exist
against the endpoint, always investigate errors in the order they are presented in
the table below. By clearing error codes associated with the
Signaling Link Status
Te s t ,
for example, you may also clear errors generated from other tests in the
testing sequence.
65 Bearer Service
Not Implemented
Requested service not implemented in switch or
endpoint.
69 Requested
Facility Not
Implemented
Requested service not supported in switch or
endpoint.
1. Consult switch and endpoint documentation to
determine service support.
Adjunct switch
error conditions
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between
the switch and the adjunct. See the CallVisor
protocol reference manual.
Table 3-132. System Technician-Demanded Tests: BRI-SET
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Signaling Link Status Test (#626) X X ND
BRI XID Test (#628) X X ND
BRI Layer 3 Query (#629) X (a) X (a) ND
BRI Remote Loop Back (#627) X (a) ND
BRI Set Audits (#630) X (a) X (a) ND