Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-497DIG-IP-STN (Digital IP Station)
3
Digital Terminal Audits Test (#17)
This is a series of tests that are classified as audits. The SPE sends messages to
the softphone application to perform the following tests. These audits run only if
the station is in-service.
Switchhook Inquiry Test This is an update of the SPE records according
to the softphone switch hook state.
Ringer Update Test This updates the softphone ringer state according
to the processor records.
Table 3-209. TEST #17 Station (Digital) Audits Test
Error
Code
Tes t
Result Description/ Recommendation
1 ABORT Switchhook audit timed out.
2 ABORT ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
4 ABORT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals a maximum of 5 times.
5 ABORT Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, the release the port via release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required for this test are not available.
2000 ABORT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Station Audits passed.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Continued on next page