Maintenance Commands
2-369test processor
2
test processor
This command performs hardware diagnostic tests on a specified processor
circuit pack.
Defaults
For SPE simplex systems, the location is optional and defaults to cabinet
1, carrier a.
Defaults for the remaining parameters are short with a repeat of 1.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
processor
location
short
long
clear
schedule
Cabinet number (
a
)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test processor
test processor schedule
test processor a
test processor 1a
test processor a sh
test processor a l c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long
clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft