DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-87AN-LN-PT (Analog Line Port)
3
1008 ABORT A ringing circuit could not be allocated. Either all of the ringing circuits are
in use, the ringing generator is defective, or it is not wired correctly.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error
Log.
3. If ABORT 1008 occurs for this test on other circuit packs as well, the
ringing generator may be defective or is not wired correctly (see
RING-GEN).
4. If an ABORT 1008 does not occur on other ports, then all four ring
phases are in use.
1018 ABORT Administration has disabled the test. The default for the Test? field on the
station form is y. Determine why this field has been set to n on this station
(this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station
extension
.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the allowable time
period. .
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The terminal equipment is not connected to the circuit pack. Some
terminal equipment, such as modems, may fail even when connected
properly.
1. Remotely test the terminal equipment.
2. If the test fails again, resolve any RING-GEN errors in the error log, if
present.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the terminal equipment may be defective. Check
and replace it, if necessary.
5. Some terminal equipment might fail even when it is connected
properly. If this is the case, disable the test using the change station
extension
command (enter n into the Test field). Note that this action
also disables Tests 6, 7, 35, and 161 on this port.