DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-351test journal-printer
2
Output
The following example shows the output for the test
isdn-testcall 80/1
command.
The responses display on a test-by-test basis with one line of data for each test
result.
Field descriptions
test journal-printer
This command performs hardware diagnostics on the link between the switch
and one of the specified journal printer links. There are two types of journal
printer links: pms-log and wakeup-log. For general information on journal printer
links, see the description of the
‘‘busyout pms-link’’
command. For information on
what a journal printer is and does, see the description of the
‘‘status journal-link’’
command.
Port
Port address: cabinet-carrier-slot-circuit
Maintenance
Name
The name of the maintenance object being tested.
Alt. Name
Alternate means of identifying the maintenance object: trunk
object
xxx/yyy
, where
xxx
= trunk group number,
yyy
=
member number
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test isdn-testcall 77/1 SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B1501 ISDN-TRK 077/001 258 PASS
Command Successfully Completed