DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-797MEDPRO (Media Processor MAPD Circuit Pack)
3
2. Re-administer this slot to match the circuit pack inserted (
change
circuit-pack
).
e.
Error Type 257
- this error is associated with the Common Port Circuit
Pack Maintenance Test. Refer to XXX-BD (Common Port Circuit Pack)
Maintenance documentation for details.
f.
Error Type 2049
- This error indicates that the operating system is down;
an attempt is made to reset the board automatically. If the reset fails, the
board is probably bad and should be replaced.
g.
Error Type 3841
- inconsistent downlink message. This error is not
service-affecting. No action is required.
h.
Error Type 3999
- indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
Error Type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If Error Type 1538 is not present, then
the circuit pack has not been taken out-of-service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.