DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-121list measurements ds-1
2
Field descriptions
list measurements ds-1
This command lists performance measurements of a DS-1 link indicating the
quality of the DS-1 physical interface between the system and a far end system.
The
ds1 summary
option provides a summary report while the
ds1 log
option
provides a detailed report.
NOTE:
The
list measurements
command has many more options than
documented here. Only those options dealing with DS1 board are
documented below.
Date
The date that the data was collected
Time
The current 15-minute interval in which the action was performed
CRC Check
The error count for CRC errors
Total
Total value of the board counter.
NOTE:
The counter value can be up to 7 digits long because the 16-
bit counter on the board. After the occurrence of an “N/A” the
delta equals the total. Busyout or release of a board or a port,
the
reset board
command, and reseating the board all clear
the firmware counters.
Delta
The difference between the current and the previous sample
Invalid Frame
The number of invalid frames detected. Invalid frames are the
frames that are misaligned.
CHAP Failures
The number of failed attempts for ppp authentication
list measurements clan ppp 1C1001 Page 1 of x
Switch Name: sierra Date:02/02/1999
C-LAN PPP PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Invalid Frame CHAP Failures
Total Delta Total Delta Total ‘Delta
02/01 03:08 85 25 185 85 5 0
02/01 02:53 60 60 100 100 5 5
02/01 02:38 N/A N/A N/A N/A N/A N/A
02/01 02:23 1000060 10 1000090 10 25 5
02/01 02:08 1000050 1000050 1000080 1000080 20 20