Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-85AN-LN-PT (Analog Line Port)
3
1 FAIL The switchhook audit failed. This result does not indicate a hardware
problem. The other updates were not performed because of this failure.
This may occur if the audit is performed at the same time the terminal
equipment goes off-hook.
1. Use the status station
extension
command to determine when the
port is available.
2. Retry the command at 1-minute intervals no more than 5 times.
3. If the test continues to fail, escalate the problem.
5 FAIL The message waiting lamp update failed. This may be an internal
software error. The translation and ringer updates were not performed
because of this failure.
7 FAIL The translation update failed. There may be an internal software error.
The ringer update was not performed because of this failure.
8 FAIL The ringer update failed. There may be an internal software error.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to fail, escalate the problem.
PASS The software and the port processor have the same status. Investigate
user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the
list configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS
command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This re-establishes the
link between the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is
inserted.
Table 3-33. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page