Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-152list testcalls
2
The measurements are produced by a set of analog trunk tests. The tests are
initiated by a maintenance demand test or by a set of scheduled tests. The
largest portion of these measurements are generated through scheduled testing
during system quiet hours (hours where the traffic volume is low). Each trunk test
performed by the system stores the results in a database. The trunk
measurements in this database reflect the state of each trunk at the time of its last
test.
Action/Object Qualifiers/Options Qualifier/Option Description
list testcalls
detail
summary
Detailed measurement report displayed
Summary measurement report displayed
grp group number Measurements for a specific trunk group displayed. When used
with the
to-grp
option, this option is the starting trunk group in a
range of user-specified trunk groups.
to-grp group number Measurements for all trunk groups from 1 to the specified
“to-grp” trunk group are displayed. When used with the
grp
option, this option is the ending trunk group in a range of
user-specified trunk groups.
mem member number Measurements for a specific trunk group member displayed.
When used with the
to-mem
option, this option is the starting
trunk group member in a range of user-specified trunk group
members.
to-mem member number Measurements for all trunk group members from 1 to the
specified “to-mem” trunk group member displayed. When used
with the
mem
option, this option is the ending trunk group
member in a range of user-specified trunk group members.
port location Measurements for a specific trunk circuit (port) displayed
result result identifier This option is used to filter out all measurement results that do
not match the user-specified result, that is, only measurement
results that match the user specified result are displayed.
Examples of results are pass, marg, fail, etc.
not-result result identifier This option is used to filter out all measurement results that do
match the user-specified result, that is, only measurement
results that do not match the user specified result are displayed.
Examples of results are pass, marg, fail, etc.
count count number This option is used to specify (limit) the number of records
displayed.
print Report sent to printer
schedule Command is validated and then a scheduling form displays to
schedule execution of the command. The command is then
placed in the command queue and is executed at the specified
time. The information displayed by the command is sent to the
system printer instead of the screen.
1
1 Refer to the Report Scheduler and System Printer feature specification for more details.