DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-135Troubleshooting Multimedia Call Handling (MMCH)
1
Diagnostics
1. The
status pnc
command on the DEFINITY SAT shows both the A-side
and B-side
State of Health
field as
partially functional
.
Action
1. Correct the ATM addresses (or swap fibers) on the A500 between the A
and B side of the EPN.
Troubleshooting Multimedia Call
Handling (MMCH)
Before troubleshooting any problems associated with the DEFINITY MMCH,
always be sure that the endpoint is operating correctly (audio, video, and data)
by making point-to-point test calls. If possible, make the test calls over the
network to test the connectivity and routing of network calls from the endpoint.
This eliminates problems such as disconnected audio or video cables and
network troubles.
64 Kbps Calls Terminate but Far End Receives
56 Kbps Indication
Description
Some 2x64 Kbps conferences on the DEFINITY MMCH do not establish because
of framing, audio, or video problems.
For calls that are routed in the network through a Lucent Technologies/LEC
interface, the originating equipment may launch a 64 Kbps call attempt, and the
far end receives either a 56 Kbps or 64 Kbps indication. If the far end receives a
64 Kbps indication, the call may have used 56 Kbps facilities. If so, the call may
exhibit any of the following conditions:
No handshaking in one direction or both (call disconnects after timeouts)
Call connects, but audio or video is corrupted (audio noise or no video)
Call succeeds without disruption (this is the least likely since one endpoint
must be aware that the call is really 56 Kbps to connect)
If any of the above conditions occur, then 64 Kbps calls from the site are
blocked.
Solution
Administer the conference for connection at 56 Kbps.