DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-310BRI-SET, ASAI-ADJ, BRI-DAT
3
1187 ABORT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out ) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release the station via
the release station command.
a. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port PCSSpp command and run the test
again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command
and run the test again. If the error is present for BRI-SET only, then
release the circuit pack via the release port PCSSpp command
and run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board
PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you release all ports associated
with it. If certain ports still need to be busied out, use the release
port PCSSpp command to busy them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 FAIL The XID-RESPONSE message was not received from the endpoint.
1. Consult the endpoint documentation to determine if the Layer 2 XID
and XID-RESPONSE messages are supported. If the documentation
reflects no support for these messages, change
XID Testing?
field to n using the change station extension command.
2. If the endpoint supports these Layer 2 messages and the test
continues to fail, assume the endpoint is defective and replace it.
PASS The switch can successfully pass messages over the D-channel to the BRI
endpoint.
Table 3-135. TEST #628 BRI XID — Continued
Error
Code
Te s t
Result Description/ Recommendation