Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-151list testcalls
2
Output
The following examples shows the output from the
list sys-link
command.
Field descriptions
list testcalls
This command generates an Automatic Transmission Measurement System
(ATMS) report. The ATMS allows the voice and data trunk facilities to be
measured for satisfactory transmission performance. The performance of the
trunks is evaluated according to measurements produced by a series of analog
tests and are compared against user-defined threshold values. The purpose of
the report is to provide measurement data to help determine the quality of trunk
lines. The measurement report contains data on trunk signal loss, noise, singing
return loss, and echo return loss.
Location
Physical location of the port associated with the system link
(cabinet-carrier-slot-circuit)
Link
Type/Channel
Type of system-link and the processor channel number of the link (if
there is one): for TN798, link type is PRI (PRI).
State
System link state:
up
or
down
Current Path
Status of the current path:
none
if the link is down;
present
if the
current path is valid
Faulted Path
Specifies the faulted path status:
present
if the link has been
faulted at least once,
none
if the link has never gone down, and
default
if the default faulted path is being used
Last Fault
Recorded
Date and time of the most recent fault
list sys-link Page 1 SPE A
SYSTEM LINKS INFORMATION
Location Link Type/ State Current Faulted Last Fault
Channel Path Path Recorded
01A0516 PRI up present present 12/30/1996 14:18
press CANCEL to quit -- press NEXT PAGE to continue