Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-290status packet-interface
2
Field descriptions, page 1
Only those fields that are different from
‘‘status link n’’
are listed here.
status packet-interface
This command displays the status of the packet-interface portion of the TN798
processor circuit pack along with link information. Link status information
including total, active, and failed links also display. When the packet-interface is
out-of-service or uninstalled, it is not used to establish and maintain links; when it
returns to in-service status, new links are again assigned to it.
Output
The following example shows the output from the
status packet-interface
command.
Destination
Name of the destination (assigned with the
add/change
data-module
command)
Destination Status
in-service/idle, in-service/active, disconnected, out-of-service,
in-service, inactive, active, idle
AC
Active channel
Destination Port
Administered port location (assigned with the
add/change
data-module
command)
Destination
Extension
Administered destination extension number (assigned with the
add/change data-module
command). This may be replaced by
Trk/Mem data (like the PI status line form) depending upon the
type of destination.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status packet-
interface
print
Report sent to printer init
inads
craft
none none
status packet-interface
PACKET INTERFACE STATUS
Location: 01A
Service State: in-service
Total Links: 32
Active Links: 32
Failed Links: 0