DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-847MMI-PT
3
Error Log Entries and Test to Clear Values
Notes:
a. The customer endpoint connected on a conference sent too many
messages to the VSP-MCU in a specified amount of time. Check the
“status conference” forms to correlate which customer had the problem.
This is a customer endpoint problem and not a VSP-MCU problem.
b. This port has been busied out by the
busyout port PCSSpp
command.
c. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, replace or reseat the circuit pack.
d. This error occurs if the MMI circuit pack detects a DSP Error. Maintenance
software will reset the DSP when this error is received. This error is logged
for all 8 resources connected to this particular DSP. If this DSP continues
to fail sanity, a Minor alarm is raised. Replace the circuit pack.
e. This error occurs when the Resource Looparound Test (#1111) fails. Run
the Long Test Sequence and note the results of Test #1111.
f. This error occurs if either the MMI or Voice Conditioner (VC) circuit packs
reports a loss of framing on the service channel between these two circuit
packs. When a customer endpoint establishes a call to the VSP-MCU, a
channel is established between the MMI resource and the VC port. If this
channel is detected to go down by either circuit pack, an uplink message
is sent. This error is then forwarded to maintenance for both circuit packs.
Table 3-367. MMI-PT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/ Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any Uplink error from pack
18 (b) 0 Busyout port PCSSpp WNG OFF release port PCSSpp
130 (c) Any Software generated WNG ON
257 (d) Any None MAJ/
MIN
ON
513 (e) Any Resource Loopback
Test (#1111)
MIN ON test port PCSSpp sh r 3
1025 (f) Any Uplink error from pack
3841 -
3844 (g)
Any Uplink error from pack