DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-228status bri-port
2
status bri-port
This command displays the service state, maintenance state and layer 1 state of
an ISDN-BRI port. This form also displays information about point-to-point
signaling links that transport over the port.
Output
For the following example shows the output from the
status bri-port 1c1701
command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status bri-port
location
print
Port location:
PCSSpp
Report sent to printer
init
inads
craft
cust
nms
browse
none none
Port:
ISDN-BRI port address.
Service State:
ISDN-BRI port is “in-service” or “out-of-service.”
Maintenance Busy?:
specifies if maintenance testing is executing on the ISDN-BRI
port (“yes” or “no”).
status bri-port 1c1701 Page 1 of 1 SPE A
STATUS BRI-PORT
Port: 01C1701
Service State: in-service
Maintenance Busy?: no
Layer 1 State: activated
TEI Value Layer2 State Endpt Extension Endpt SPID Service SPID?
Link1 64 13-established 1010 1010
Link2
Link3